Physics Chapter 11 : Topic 15

Galvanometer and Null Methods

1 / 30

The main function of a galvanometer in a null method is to:

2 / 30

A galvanometer shows zero deflection in a null method when:

3 / 30

The use of a galvanometer in a potentiometer is based on the principle of:

4 / 30

A galvanometer is preferred in null methods because it is:

5 / 30

In a potentiometer experiment, zero galvanometer deflection indicates that:

6 / 30

The condition of zero current through a galvanometer is called:

7 / 30

In a null method, the galvanometer should ideally have:

8 / 30

When a galvanometer shows deflection in a potentiometer circuit, it means:

9 / 30

The main advantage of using a galvanometer in a null method is that it:

10 / 30

A galvanometer is connected between two points in a potentiometer. At balance, the potential difference between these points is:

11 / 30

The sensitivity of a galvanometer refers to its ability to:

12 / 30

In a null method, the galvanometer acts as:

13 / 30

If the galvanometer in a potentiometer shows a deflection, the jockey should be:

14 / 30

If the galvanometer deflects to one side, it indicates:

15 / 30

Reversing the connections of a galvanometer will:

16 / 30

A galvanometer in a null method is not used to measure:

17 / 30

In a potentiometer, the galvanometer is connected between:

18 / 30

A galvanometer gives zero deflection because:

19 / 30

The accuracy of a potentiometer measurement depends on a galvanometer having:

20 / 30

In a null method, the measurement is made when the galvanometer reading is:

21 / 30

The galvanometer in a potentiometer experiment protects the cell being measured from:

22 / 30

A moving coil galvanometer works because a current-carrying coil experiences:

23 / 30

In a balanced potentiometer circuit, the galvanometer resistance affects:

24 / 30

The galvanometer is called a null detector because it:

25 / 30

In a Wheatstone bridge experiment, the galvanometer is used to:

26 / 30

If the galvanometer is replaced by an ordinary ammeter in a null method:

27 / 30

A very small deflection of a galvanometer indicates:

28 / 30

The use of a galvanometer in null methods improves accuracy because:

29 / 30

In a potentiometer, if the galvanometer shows zero deflection at $\mathbf{80\ cm}$, this length represents:

30 / 30

The most important characteristic of a galvanometer used in null methods is: